Dec 27, 2009

DAIKIN AIRCON ERROR CODES

While I was working as engineer in electronic goods trading company in Yangon, I was posted as an in-charge person for repairing electronic goods in Service Department. As for our company, even though we were using the logo of the product as name of service center, it was not a really supported service department from Mother Company like other service centers in Singapore. Most of the time, we can solve all the complaints regarding to faulty of the products, sometime cannot. We really know that some of the high tech products have already built –in fault finding systems, showing errors on display of the equipments or in display of the remote controllers. But, sometime we really do not have the correct procedure how to solve this error.

For example, one time, our company brought in one type of air-conditioners that was floor-standing type and that was the most trouble making equipments we have experienced ever. As you all know, the electric power supply in Burma is not stable and frequently tripped. So that, most of the electronic equipments with high sensitivities are not being able to stay up to its life time. Most of the equipments are defective as of the fluctuation of electrical power supply.

I still can remember that type of air-conditioners show up error E2, description said that intercommunication errors. We really do not have solution to solve. But, as of urgency of equipments to be able to operate, we took out the same control PCB card from new equipments and replace it. The faulty machine could resume its operation immediately but the same machine in warehouse left NO PCB.

But, by the time sale department want to sell out the machine in warehouse, there have some disputes in meeting. I just want to recall my memory of the days I have experienced in errors given by these machines.

As much as the machines became more intelligent, it helps technicians to find faults and solve the faulty parts in short time. But, if we do not have this error codes, it is more troublesome for us. The following are the error codes for DAIKIN air-conditioners. It will be useless if you are not in field of air-conditioning, but will be precious if you are working as air-conditioning systems related jobs.

In Myanmar, DAIKIN also have certain percentage of market share in Air-conditioning and Refrigeration Systems, so that if you need to face with DAIKIN, the following error codes will help you to solve your Air conditioners’ problems.

PROCEDURES TO TEST WITH REMOTE CONTROLLER

If your DAIKIN remote controller comes with a "test" button, use it. Otherwise press the Temperature UP, Temperature DOWN and the MODE buttons all at the same time. I repeat all 3 buttons at the same time.

You will see 00 on the remote controller. The first "0" will be blinking.
Stand facing the particular air conditioner you wanted to test.

Now press the Temperature UP button, "0" will become "A" and the air conditioner will respond with either a single beep or double beep.

Carry on pressing the Temperature UP button and listen to the beeping sound, stop when you hear a double beep. For example: it is now showing "C0".

Now press the MODE button, the second "0" will be blinking.
Now press the Temperature UP button, "0" will become "1" and the air conditioner will respond with either a double beep or a continuous beep.

The continuous beep is the error code. For example "C4", it means it is a faulty liquid pipe thermistor

DAIKIN ERROR CODES:

AO Indoor Error of external protection device
A1 Indoor PCB defect
A3 Indoor Malfunction of drain Level control system
A5 Indoor Freeze-up prevention
A6 Indoor Fan motor lock, Overload
A7 Indoor Malfunction of swing motor flap
A9 Indoor Malfunction of EEV
AF Indoor Drain level above limit (clogging)
AJ Indoor Malfunction of capacity set device
C3 Indoor Malfunction of drain thermistor
C4 Indoor Malfunction of liquid pipe thermistor
C5 Indoor Malfunction of gas pipe thermistor
C7 Indoor Lower louvre limit switch/motor
C9 Indoor Malfunction of air thermistor
CC Indoor Malfunction of moisture sensor
CA Indoor Malfunction of discharge air thermistor
CJ Indoor Malfunction of remote control thermistor
CE Indoor Malfunction of radiant heat sensor
E0 Outdoor Activation of outdoor safety device
E1 Outdoor PCB defect
E3 Outdoor Activation of high pressure switch
E4 Outdoor Activation of low pressure switch
E5 Outdoor Activation of compressor over heat protection
E5 Outdoor Compressor motor lock
E6 Outdoor Compressor start up error
E6 Outdoor Standard compressor lock/over current
E7 Outdoor Fan motor lock, Overload
E8 Outdoor Inverter input over current
E9 Outdoor Malfunction of EEV
EA Outdoor Four way valve defective
F3 Outdoor Abnormal discharge pipe temperature
F6 Outdoor Refrigerant overcharged
FC Outdoor Low pressure drop.
H3 Outdoor High pressure switch defect
H4 Outdoor Low pressure switch defect
H6 Outdoor Compressor motor position detection sensor error
H7 Outdoor Fan motor position detection sensor error
H8 Outdoor Current transformer error
H9 Outdoor Malfunction of air thermistor
J1 Outdoor Malfunction of pressure sensor
J2 Outdoor Current sensor malfunction
J3 Outdoor Malfunction of discharge pipe thermistor
J4 Outdoor Low pressure saturation thermistor
J5 Outdoor Malfunction of suction pipe thermistor
J6 Outdoor Malfunction of heat exchanger thermistor
J7 Outdoor Malfunction of heat exchanger liquid thermistor
J8 Outdoor Malfunction of liquid pipe thermistor
J9 Outdoor Malfunction of gas pipe thermistor
JA Outdoor Malfunction of discharge pipe pressure sensor
JC Outdoor Malfunction of suction pipe pressure sensor
JH Outdoor Malfunction of oil temperature sensor
L0 Outdoor Malfunction of inverter
L3 Outdoor Electronic component box overheat
L4 Outdoor Inverter cooling defect
L5 Outdoor Comp motor ground fault, Short circuit
L6 Outdoor Compressor motor grounding/short circuit
L7 Outdoor Total input overcurrent
L8 Outdoor Comp overload, Motor disconnected
L9 Outdoor Compressor lock
LA Outdoor Power unit malfunction
LC Outdoor Transmission between inverter & outdoor
P1 Outdoor Inverter over ripple
P3 Outdoor Thermistor abnormality
P4 Outdoor Power unit humidity sensor malfunction
PJ Outdoor Failure of capacity set resistor
U0 System Shortage of refrigerant or EEV failure
U1 System Negative phase, Open phase
U2 System Power supply insufficient
U3 System Wiring check operation not executed
U3 System Mismatch of indoor and outdoor units (Split only)
U4 System Transmission between indoor units
U5 System Transmission to remote controller
U6 System Malfunction transmission outdoor to BP unit
U7 System Transmission between outdoor units
U7 Outdoor Malfunction between outdoor boards(RMX/RX RK)
U8 System Transmission between master & slave R/C
U9 System Transmission error between indoor to outdoor
UA System Excessive number of fancoils
UC System Address duplication of central controllers
UE System Transmission error between indoor & central
UF System Refrigeration system not set/wiring - piping
UF System Terminals 1 and 3 crossed (Split/Skyair)

Credit to refrigerationengineer.com

Dec 22, 2009

Master TOEFL Reading, Writing & Vocabulary

Being my religion is Buddhism, we believed in past life. All the things good or bad we have experienced in this life are consequences of the things we have done in past lives. If we have done good deeds in past life, we can have or achieve good things in current life. In other way round, to be able to get good things in next lives, we have to do good deeds in present life. This is one of the reasons I am sharing the things on my blog.

It was the precious habit that I received from my dad that is reading. Since my childhood, I have read so many books that were collected by my dad. I don't care whatever I understand the subject inside the books or not, I read all the books I can read. All the pocket money given by my mom was also used for buying books. The old books shops in the downtown of Rangoon are the area I like most to walk around. As of always I was buying these old books and not using for eatery things, my mom warned one time that "I won't give you pocket money anymore if you still go and buy these books..." This is also my hobby of collecting books. Now, internet age, I like internet so much as of I can find a lot of things I want on it. And, also all the things I found on internet also I want to share. It is also one of the ways I was making good deeds by sharing knowledge to whom need it.

So now, here are three books of TOEFL training for Reading, Writing and Vocabulary. I hope it will helpful to who are studying English As Foreign Language. Please click on the book covers to download them.

Click me to download this book!!! Click me to download this book!!! Click me to download this book!!!

Dec 18, 2009

Mistaken

Just want to feature a music video that was sung and starring by Arakan singer. Actually I really do not know when this music video was released. Just a month ago, by the time I was surfing YouTube, just finding Arakan music videos, I have seen this and view it. It attract my mind, I replay so many times. The song is composing about the disease endangering the world, AIDS.

I am not too sure it is own tune music, but the pattern that I can listen shows that it seems to be own tune. The most significant thing I like in this music video is its performance. The way they present theme of song I like it.

Song's name is မွားမိလို႕(Mistaken).

I hope you all will like it too, have fun for watching..,

:)

Dec 15, 2009

Future of Foreign Workers Beyond IRs

Today morning, when I was on the bus from Harbour Front to RWS site office, I saw so many workers near to Sentosa Gate (Arch). Seeing so many workers in this place is not new to me as of there are nearly twenty or thirty thousand of workers are working in this Sentosa IR project. This is the time they go into site and start a day of work. But, the scene today I saw was quite strange. Most of them are carrying huge luggage, they are looks alike going to start trip to somewhere. Somewhere...??? Which place will be somewhere they supposed to go? That's their hometown.

Of course, now the project is nearly end. There are a few tens of thousand of workers will be released from this project. And currently there are two of the biggest projects holding several thousands of workers are going to end soon. They are known as two IRs, one is Sentosa IR called Resorts World at Sentosa and another one is Marina Bay Sands.

As you all know, so many countries including Singapore were affected by global financial recession last year, several business sectors were affected, several thousands of workers are un-employed, some are retrenched, and wages cut out, so and so... But, construction sectors usually delay in effects. The reason is the projects that are running, on-going are bid-and-win in previous years. So, the effect of recession, lesser in projects will affect the construction sector by subsequent year, may be in 2010. Furthermore, not only Singapore, but also some of the countries in region were spoke out that they will try to be lesser dependent on foreign workers resources.

So, how does it affect to foreign workers? Of course, there will be huge impact on foreign workers. Now, start from this week there will be lesser and lesser workers on site. Especially workers from China, they are people who are going back to home first, the second batch will be second big amount of workforce who are Indian. And, after that, how about workers like us? If there is lesser construction projects and local government will emphasize to satisfy local people, how we all can survive.

We should have more diligence to play safe in next year in our working environment to be able to survive in construction industry. Now, the Cheese we are relying became lesser and lesser, so what should we do? Shall we go and find other place which cheese we like is abundant? That place, could it be our homeland?

The thing we are sure is better to be prepared!

Dec 13, 2009

Universal Studio Singapore

In this December, Mgluaye is super busyyyyy.... And my blog also got some configuration difficulties after Google migrated file hosted in Google Pages to Google Sites. Today, actually I got fever and resting at home, I tried to repair my blog, change some configuration and appearance also. But, there some items like drop-down menu below banner, blog feed still need to add in. I think I will be able to do it in this week. Have to try!!!

Now construction project of Universal Studio Singapore is coming to end and targeting to have soft opening on 22nd December. A lot of unfinished works were still there and everybody got over-stressed, a lot people still need to work over the weekend. As for me, as of I am getting fever today, so resting at home but still doing some office works from home. :(

Ok. Here are some of the photos taken in Universal Studio Singapore, hope you all to have fun...

Icon Globe of Universal Studio at the Entrance

Entrance

Ship from City of New York and Battlestar Galatica

Lagoon & NY Ship

New York Ship (The two layers of roof you saw on photo is Discovery Center in Lostworld)

NY Ship

Guards From Revenge of the Mummy

Warden @ Mummy

The below food cart supposed to sell food by mummy???

Food Cart

Entrance to the Jurassic Park

Jurrasic Park

Fashion Store for Lady-Dinosaur

Jurrasic Outfitter

Stay tuned! I'll try to upload some more if I got spare time.

:)

Dec 10, 2009

2009 November Currency Review

2009 ခုႏွစ္ ႏို၀င္ဘာလ အတြင္းမွာ စကၤာပူေဒၚလာနဲ႕ ျမန္မာေငြ လဲလွယ္ႏံႈး တစ္လလံုး ပ်မ္းမွ် 721.5 က်ပ္ ေပါက္ခဲ႕ၿပီး ႏို၀င္ဘာလ 1 ရက္ေန႕မွာ အျမင္႕ဆံုး 762 က်ပ္ ထိ ေပါက္ခဲ႕ၿပီး၊ ႏို၀င္ဘာလ 18 ရက္နဲ႕ 19 ရက္ေတြမွာ အနိမ္႕ဆံုး 700 က်ပ္ ေပါက္ခဲ႕ပါတယ္။

2009 ခုႏွစ္ ႏို၀င္ဘာလ အတြင္းမွာ အေမရိကန္ ေဒၚလာနဲ႕ စကၤာပူေဒၚလာ လဲလွယ္ႏံႈး တစ္လလံုး ပ်မ္းမွ် 1.389076 ေပါက္ခဲ႕ၿပီး ႏို၀င္ဘာလ 1 ရက္ေန႕မွာ အျမင္႕ဆံုး 1.40377 ထိ ေပါက္ခဲ႕ၿပီး၊ ႏို၀င္ဘာလ 25 ရက္ေန႕မွာ အနိမ္႕ဆံုး 1.37927 ေပါက္ခဲ႕ပါတယ္။

ျမန္မာေငြနဲ႕ စကၤာပူ ေဒၚလာ လဲလွယ္ႏံႈးကို ေမာင္လူေအး Sidebar ထဲက အခ်က္အလက္ေတြနဲ႕ ျပဳစုၿပီး အေမရိကန္ ေဒၚလာနဲ႕ စကၤာပူေဒၚလာ လဲလွယ္ႏံႈးကိုေတာ႕ http://www.exchange-rates.org ကေန ရယူပါတယ္ဗ်ား။

SGD - MMK NOV

SGD - USD NOV

Related Post

သူတို့ဖျက်ကြလေပြီ

Unicode Version မောင်လူအေးတို့ ဘီအိုအိပ်ချ် ရုံးတည်ရာ လှိုင် ၂ ရပ်ကွက်၊ ရတနာမွန် အိမ်ယာအတွင်းက လမ်းများမှာ ယခု ရက်သတ္တပတ်အတွင်...